Destructive Testing on Alloy Chain Sling in STL test site

cart 0
cart 0
News & Events - Inner Banner

News & Events

Destructive Testing on 2-legged Chain Sling in SING TECK LEONG, STL Test Site

calendar icon November 24, 2022

On request by our value customer, a set of 10mm X 2 legged Alloy Chain Sling was put under Proof load (hold) test followed by a destructive test to examine the sling performance under max load on our in-house 100T Talurit Test Bed. 

Test gear rated capacity at 4,000kg, max load at 8,000kg. 

We performed a loading to 8,000kg followed by 12,000kg; a visual examination shows no defects from both loading.  

 ( Loading profile below) 

8Ton-Load-Test-Alloy-Chain-Profile-STL12Ton-Load-Test-Alloy-Chain-Profile-STL

After both Load Hold Test, we proceed for the finale of maximizing the load testing till failure, the Destructive Test.

We did a short video clip on the timed failure mode of the alloy chain sling under destructive testing...check out the clip below!

(note that the clip has been shorten with speed-mode) 

  Profile Charting on the failure mode:

Test Gear encounter fracture on loading at 21T! This break load is ~5X Rated Capacity of the 4T test gear...  

Destructive-Test-Alloy-Chain-Profile-STL

Feel free to contact us for inquiries, if your organization needs any load testing service or rigging solutions... we will be glad to assist you with our expertise.

 

To check out more test services provided by STL, refer to the link below:

LINK: STL Test Services

 

 

 

Destructive Testing on 2-legged Alloy Chain Sling at STL test site
Posted by T.F